In Denver, a house can meet every line of the building code and still be refused a permit. The reason is zoning. A roof that pokes a foot through the bulk plane, an addition that uses up the last of the building coverage, a front porch that steps past the neighbors' setback: none of these is a building code problem, and each one stops a permit just the same. In a 2026 case, Denver's Board of Adjustment heard a homeowner in a U-SU-C district who needed a variance because the roof of an addition crossed the side bulk plane.
This guide explains how the Denver Zoning Code works for houses, additions and backyard ADUs: how to read your zone district, which tables to look in, and what the zoning reviewer checks on your site plan. It is written for homeowners and contractors planning work, so you can find the limits before anything is drawn.
Zoning and the building code are two different reviews
Denver reviews a residential permit twice. The building code review asks whether the house is safe to build and live in: structure, egress, fire separation, energy, and the rest of the International Residential Code with Denver's amendments. We covered that side in our guide to Denver permit drawings and CPD submittals.
The zoning review asks whether the building is allowed there, at that size and in that shape. Both reviews are done by Community Planning and Development (CPD), both have to pass, and the zoning answer is the one to know first, because it sets the box everything else has to fit inside.
Start with your zone district
Every lot in Denver carries a zone district name, such as U-SU-C, E-SU-D or U-TU-B. You can look yours up on the city's online zoning map. The name is a code with three parts:

- The neighborhood context (the first letter) tells you which article of the zoning code applies. S- is Suburban, E- is Urban Edge, U- is Urban, G- is General Urban, C- is Urban Center and D- is Downtown. Most of Denver's older single-family neighborhoods are U- or E-, and newer subdivisions are often S-.
- The building types allowed (the middle letters). SU allows a single-unit house, TU a duplex or two-unit form, RH row houses, MU multi-unit buildings, and MS and MX main street and mixed-use buildings.
- The minimum zone lot (the last letter). Each letter sets a minimum lot area and width, and in the tables, many standards such as setbacks and coverage change with it.
A few properties still carry zoning from Denver's previous code, known as Former Chapter 59, or a Planned Unit Development (PUD) with its own rules. If your map shows something that does not follow the pattern above, the standards are in that document instead.
Building forms: the shape your house is allowed to take
The Denver Zoning Code is a form-based code. Instead of one set of rules per district, each district allows certain building forms, and each form has its own table of standards. In the Urban (U-) context, the main form for a detached home is the Urban House, which the code describes as one to two and a half stories, with the narrow side facing the street and parking from an alley where there is one. The Suburban context has a Suburban House form. Two-unit districts add duplex and tandem house forms, and almost every residential district now also has a Detached Accessory Dwelling Unit form.
When you read the code, find your neighborhood context's article, then the building form tables for your district. That table is where every number for your project lives.
What the zoning reviewer checks
Height, measured from base planes
Height is not measured from the lowest point of the ground. Denver uses base planes, reference planes worked out from the grade at the lot corners. For the Urban House form the lot is split at 65% of its depth, front to back, with its own base plane for each part, and the form allows more height in the front 65% than in the rear 35%. That rule keeps the tall part of the house near the street and the back yard open. Every height on your elevations has to be measured from the right base plane.
The bulk plane
The bulk plane is the rule that surprises people. Picture a line rising straight up from each side lot line to a set height, then sloping in toward the middle of the lot. In the Urban neighborhood tables the slope is 45 degrees. The house, roof included, has to fit inside that envelope. The bulk plane limits tall walls built close to the side lot lines, and it decides whether a steep roof or a second-storey addition fits on a narrow lot.
The vertical height at the lot line and the slope come from your district's table. The code lists a small number of features allowed to project through the bulk plane, each with its own limits; anything not on that list has to stay inside. When it does not, the choices are to change the roof or ask the Board of Adjustment for a variance, which takes time and is not assured.
Setbacks
- Primary street setback. In many Denver districts the front setback is block sensing: rather than one fixed number, it is worked out from the houses on either side of yours, so a new house or addition lines up with the street it is on. The method is in the code's rules of measurement.
- Side setbacks usually grow with the width of the lot, and some districts set a minimum for one side and a combined minimum for both.
- Rear setbacks depend on whether the lot has an alley.

Building coverage
Coverage is the share of the lot covered by building footprints. It adds up the house, the garage and an ADU, so a large addition can use up the coverage an ADU later needs. If both are in your future, plan them together.
Backyard ADUs in Denver
Detached ADUs used to be allowed only in the districts that named them. After Denver's 2023 "ADUs in Denver" update and Colorado's 2024 ADU law, a detached ADU can be built alongside a house in nearly all of the city's residential districts. An ADU uses its own building form, with its own height, footprint and setback limits, usually lower and smaller than the house. Two-storey ADUs generally need deeper setbacks or an alley, and most published summaries of the current rules give a maximum height of 24 feet for a two-storey ADU. Denver no longer requires the owner to live on the property, and Colorado's 2024 ADU law (HB24-1152) bars that requirement in cities it covers.
An ADU also counts toward building coverage, needs its own utility connections planned, and goes through the same building code review as a house. Our detached ADU drawings guide covers the sheets reviewers check first.
What the site plan has to show
A zoning reviewer reads one sheet more than any other: the site plan. For a Denver house, addition or ADU, expect to show:
- The zone district and the building form you are using
- Lot dimensions and area, from a survey where you have one
- Every setback, dimensioned to the property lines, with the block-sensing calculation for the front setback where it applies
- Building coverage: each footprint's area and the total as a percentage of the lot
- The base planes and heights on the elevations, and the bulk plane drawn on the side elevations or a section
- Existing structures to remain or be removed, driveways, and the alley if there is one
Most zoning corrections come from the same few gaps: a setback dimensioned to the fence instead of the property line, coverage that leaves out a shed or garage, or elevations with no bulk plane drawn, so the reviewer cannot tell whether the roof fits. If your set does come back with comments, our page on plan check corrections explains how a response goes together.
Check zoning before you design
The cheapest moment to find a zoning limit is before the design is drawn. Before you pay for plans:
- Look up your zone district on the city's map, and check for an overlay or an older zoning ordinance
- Find your building form's table in the code and note the height, bulk plane, setbacks and coverage
- Measure your neighbors' front setbacks if your district uses block sensing
- Add up what is already on the lot, so you know the coverage left
- If the project is close to a limit, ask CPD before you design, not after
How we help
We draft permit sets for Denver projects: site plans with the setbacks, coverage and block-sensing numbers worked out, elevations with base planes and the bulk plane drawn, and the architectural sheets the building review needs. If you do not have drawings of the existing house, we start from as-built drawings made from your plans, photos or a phone scan.
Send us your address and what you want to build and we will come back with a fixed quote, usually within a couple of hours. Or see what goes into a permit drawing set.
This guide explains how the Denver Zoning Code is organized. The numbers for your lot come from the current code tables for your zone district, and CPD makes the final zoning determination.
Related calculators & drafting services
Check your numbers with the free calculators, or have the sheets drawn by the studio.
Interactive Permit Calculators
NEC 220 Electrical Panel Sizing Calculator
Verify if an existing 100A or 200A residential service can handle an ADU, heat pump, or addition without a costly utility upgrade.
Plumbing Fixture Unit (WSFU/DFU) Sizer
Check if existing water meter and sewer lateral pipe diameter satisfy IPC/UPC code requirements for new bathrooms.
Permit Drafting Services
Permit Drawing Sets for Additions & ADUs
Turnkey architectural, structural, and MEP sets formatted for municipal plan-check submittal with 2 revision rounds included.
Structural Drafting: Framing & Foundations
Continuous footing details, post-tension slabs, shear wall schedules, and LVL ridge beam callouts for city submittal.